EasyManuals Logo

ADTRAN Total Access 5000 Deployment Guide

ADTRAN Total Access 5000
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #293 background imageLoading...
Page #293 background image
Appendix I, 5.1 Provisioning Defaults - Total Access 5000 Provisioning Defaults
65K510DEP08-1A I-17
alarmdescriptionexternalinput2 ʺExtAlmInput2ʺ
alarmdescriptionexternalinput3 ʺExtAlmInput3ʺ
alarmdescriptionexternalinput4 ʺExtAlmInput4ʺ
alarmdescriptionexternalinput5 ʺExtAlmInput5ʺ
alarmdescriptionexternalinput6 ʺExtAlmInput6ʺ
alarmdescriptionexternalinput7 ʺExtAlmInput7ʺ
alarmdescriptionexternalinput8 ʺExtAlmInput8ʺ
alarmdescriptionexternalinput9 ʺExtAlmInput9ʺ
alarmdescriptionexternalinput10 ʺExtAlmInput10ʺ
alarmdescriptionexternalinput11 ʺExtAlmInput11ʺ
alarmdescriptionexternalinput12 ʺExtAlmInput12ʺ
alarmdescriptionexternalinput13 ʺExtAlmInput13ʺ
alarmdescriptionexternalinput14 ʺExtAlmInput14ʺ
alarmdescriptionexternalinput15 ʺExtAlmInput15ʺ
alarmdescriptionexternalinput16 ʺExtAlmInput16ʺ
alarmdescriptionpowerfailac ʺACPowerFailʺ
alarmenableexternalinput1 Enabled
alarmenableexternalinput2 Enabled
alarmenableexternalinput3 Enabled
alarmenableexternalinput4 Enabled
alarmenableexternalinput5 Enabled
alarmenableexternalinput6 Enabled
alarmenableexternalinput7 Enabled
alarmenableexternalinput8 Enabled
alarmenableexternalinput9 Enabled
alarmenableexternalinput10 Enabled
alarmenableexternalinput11 Enabled
alarmenableexternalinput12 Enabled
alarmenableexternalinput13 Enabled
alarmenableexternalinput14 Enabled
alarmenableexternalinput15 Enabled
alarmenableexternalinput16 Enabled
Table I-26. System Alarm Defaults (Continued)
Provisioning Option Default Setting

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.