lwzu
Load Word and Zero with Update
Preliminary User’s Manual
lwzu
Load Word and Zero with Update
EA ← (RA) + EXTS(D)
(RA)
← EA
(RT)
← MS(EA,4)
An effective address (EA) is formed by adding a displacement to the base address in register RA. The displace-
ment is obtained by sign-extending the 16-bit D field to 32 bits. The EA is placed into register RA.
The word at the EA is placed into register RT.
Registers Altered
•RA
•RT
Invalid Instruction Forms
•RA=RT
•RA=0
Architecture Note
This instruction is part of the PowerPC User Instruction Set Architecture.
lwzu RT, D(RA)
33 RT RA D
0 6 11 16 31