Variable Value
TestDone Indicates whether the TDR test is complete
(true) or not (false).
CableStatus Indicates the status of the cable as a
summation of the status of the cable
conductor pairs.
• 1—Fail: the cable is experiencing any
combination of open and shorted pairs
•
2—Normal: the cable is operating normally
with no fault found
Pair1Status Indicates the status of the first pair in the
cable. Values include:
• 1—pairFail
• 2—pairNormal
• 3—pairOpen
• 4—pairShorted
• 5—pairNotApplicable
• 6—pairNotTested
• 7—pairForce
• 8—pinShort
Important:
If a 10MB or 100MB link is established
without autonegotiation, Pair 1 returns
Forced mode. The pair length is
meaningless in this case.
Pair1Length Indicates the length of the first pair in the
cable, in meters, measured by the TDR.
Pair2Status Indicates the status of the second pair in the
cable. Values include:
• 1—pairFail
• 2—pairNormal
• 3—pairOpen
• 4—pairShorted
• 5—pairNotApplicable
• 6—pairNotTested
• 7—pairForce
• 8—pinShort
System configuration using Enterprise Device Manager