Parameter
Name / value range / [default setting]
Info
0x2631:012
(P400.12)
Function list: Activate keypad control
(Function list: Keypad control)
For further possible settings, see parameter
0x2631:001 (P400.01).
364
Assignment of a trigger for the "Activate keypad control" function.
Trigger = TRUE: activate keypad as control source.
Trigger = FALSE: no action / deactivate keypad as control source again.
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2631:037
(P400.37)
Function list: Activate network control
(Function list: Network control)
For further possible settings, see parameter
0x2631:001 (P400.01).
364
Assignment of a trigger for the "Activate network control" function.
Trigger = TRUE: Activate network control.
Trigger = FALSE: No action / deactivate network control again.
0
Not connected
No trigger assigned (trigger is constantly FALSE).
114
Network control active
(from version 02.00)
TRUE if the network control is requested via bit 5 of the AC drive control
word 0x400B:001 (P592.01). Otherwise FALSE.
Notes:
Set this selection if the network control is to be activated via bit 5 of
the AC drive control word.
The AC drive control word can be used with any communication
pro
tocol.
AC Drive Profile
188
0x2824
(P200.00)
Control selection
(Control select.)
Selection of the type of inverter control.
0
Flexible I/O configuration
This selection enables a flexible assignment of the start, stop, and
rotating direction commands with digital signal sources.
Digital signal sources can be digital inputs, network and keypad.
The I/O configuration is made via the parameters 0x2631:xx (P400.xx).
1
Keypad
This selection enables the motor to be started exclusively via the start
key of the keypad. Other signal sources for starting the motor are
ignored.
Start motor Stop motor
Note!
The functions "Enable inverter" 0x2631:001 (P400.01) and "Run"
0x2631:002 (P400.02) must be set to TRUE to start the motor.
If jog operation is active, the motor cannot be stopped via the
keypad key.