PU comm error
PU: communication error
Fault
-
If this error occurs, the motor may not be able to be brought to standstill anymore. If
communication is lost completely, the power output stage will switch off.
Notes:
Serious error: The inverter is inhibited immediately. The motor becomes torqueless
SDO communication with PU aborted
Serious error: The inverter is inhibited immediately. The motor becomes torqueless
Notes:
Logging only (Error history buffer/Logbook)
Notes:
Logging only (Error history buffer/Logbook)
25008
0x61B0
PU uC supply err
PU: uC supply voltage drop down
Fault
-
A supply voltage drop for the microprocessor of the power unit has been detected.
Serious error: The inverter is inhibited immediately. The motor becomes torqueless
Trigger/functions connected incorrectly
The assignment directives have not been observed:
If the "flexible I/O configuration" is active as control source, the "Enable inverter"
func
tion or the "Run" function must be connected to a digital input in order that the
motor can be stopped again any time!
In case of keypad or network control, the two functions "Enable inverter" and "Run" can
also be set to "Constant TRUE [1]" to start the motor.
The use of the "Start forward (CW)" and "Start reverse (CCW)" functions excludes the
use of the "Run forward (CW)" and "Run reverse (CCW)" and vice versa.
Start / stop motor
363
The "Activate fault 1" function was triggered via the flexible I/O configuration.
The error can only be reset after the function has been deactivated again.
Triggering a user-defined fault
406
The "Activate fault 2" function was triggered via the flexible I/O configuration.
The error can only be reset after the function has been deactivated again.
Triggering a user-defined fault
406
The "Invert rotation" function was requested with an active limitation of rotation.
Motor
rotating direction
153
Notes:
Logging only (Error history buffer/Logbook)
Maximuml allowed troubles exceeded
314
0
The "Activate fault" function was triggered via the AC drive control word.
The error can only be reset after the function has been deactivated again.
The "Activate fault 1" function was triggered via the NetWordIN1 data word.
The error can only be reset after the function has been deactivated again.
Further process data
191