486 01-6203-01R3, CG Drives & Automation
Error code
Info
Error type
Adjustable in
dec
hex
Keypad display
Error message
The maximum possible torque has been reached and the deceleration time set in
0x2D67:002 (P329.02) has elapsed.
Motor torque monitoring
164
(P329.01)
36992
0x9080
Keypad removed
Keypad removed
Fault
-
The keypad was removed while the keypad control was activated.
Remedy:
Plug on the keypad again or
activate another control source.
Control source change-over
358
65282
0xFF02
BrkResistor OL.F
Brake resistor: overload fault
Fault
-
Error message is not available for the inverter Emotron VS10/30.
Notes:
The error can only be reset after a blocking time of 5 s.
65285
0xFF05
STO error
Safe Torque Off error
Fault
-
Notes:
Serious error: The inverter is inhibited immediately. The motor becomes torqueless
(coasts).
The error can only be reset by mains switching.
65286
0xFF06
Motor overspeed
Motor overspeed
Fault
0x2D44:002
(P350.02)
The motor speed has reached the error threshold for overspeed set in .
Motor speed monitoring
164
Notes:
The error can only be reset after a blocking time of 1 s.
65289
0xFF09
Mot.Phase miss.
Motor phase missing
No response
0x2D45:001
(P310.01)
A failure of several motor phases has been detected.
Remedy:
Check wiring between inverter and motor.
In case of a false tripping, adapt the settings for the motor phase failure detection.
Motor phase failure detection
163
Notes:
The error can only be reset after a blocking time of 2 s.
65290
0xFF0A
Phase U failure
Motor phase failure phase U
No response
0x2D45:001
(P310.01)
A failure of the motor phase U has been detected.
Remedy:
Check wiring between inverter and motor.
In case of a false tripping, adapt the settings for the motor phase failure detection.
Motor phase failure detection
163
Notes:
The error can only be reset after a blocking time of 2 s.
65291
0xFF0B
Phase V failure
Motor phase failure phase V
No response
0x2D45:001
(P310.01)
A failure of the motor phase V has been detected.
Remedy:
Check wiring between inverter and motor.
In case of a false tripping, adapt the settings for the motor phase failure detection.
Motor phase failure detection
163
Notes:
The error can only be reset after a blocking time of 2 s.
65292
0xFF0C
Phase W failure
Motor phase failure phase W
No response
0x2D45:001
(P310.01)
A failure of the motor phase W has been detected.
Remedy:
Check wiring between inverter and motor.
In case of a false tripping, adapt the settings for the motor phase failure detection.
Motor phase failure detection
163
Notes:
The error can only be reset after a blocking time of 2 s.
65305
0xFF19
Motor ID fault
Motor parameter identification fault
Fault
-
During the automatic identification of the motor, an error has occurred.

Table of Contents