Cordex®CXCHPControllerSoftwareManual|22-Usingcustomviews,data,timers,counters,scheduler,andcustomactions
Initialize Source: ThisoptionalfieldisusedtorepresenttheInitialize value.Itisusuallysettothe
resultofacustomdata.
Initial Value: TheinitialvalueoftheDown Counter.
Therearealsosomefieldstodescribethestateofthecounter:
Input: ThevalueofthefieldthatwasselectedfortheInput Source.Itwillevaluatetofalseortrue.
Output: Thevalueofthecounter.
Initialize: ThevalueofthefieldthatwasselectedfortheInitialize Source.Itwillevaluatetofalse
ortrue.
Counter at Zero: ThisvalueistruewhenthecounterOutput isequaltozero.
ThecounteralsohasaReinitialize Counter button.Whenthisbuttonispressed,thecounterOutput is
setbacktotheinitialvalue.
Down counter operation
Thedowncounteroperatesasfollows:
WhentheInput valuegoesfromfalsetotrue,theOutput willdecrementbyone,aslongasitis
greaterthanzeroandtheInitialize valueisfalse.
WhentheInitialize valueistrue,theOutput willalwaysbeequaltotheInitial Value.
TheCounter at Zero valuewillbetruewhenevertheOutput isequaltozero.
WhentheReinitialize Counter buttonispressed,thecounterOutput issettotheInitial
Value.ThisallowsforamanualresetofthecounterincasetheInitialize Source hasnotbeen
configured.
22.5. Scheduler
TheScheduler featuremakesitpossibletocreateactionswhichcanoccurorrecuratspecifictimesor
dates.Withthisfeatureyoucan:
Scheduleasingleaction.
Schedulearecurringaction,hourly,daily,weekly,ormonthly.
TheScheduler canbeusedtodothefollowing:
EqualizethebatteriesonaDCsystem.
RunabatterytestonaDCsystem.
PutaDCsystembackintofloatmode(cancelinganyequalizeorbatterytest).
0350058-J0 Rev AL Page 249

Table of Contents

Other manuals for EnerSys Alpha Cordex CXC HP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EnerSys Alpha Cordex CXC HP and is the answer not in the manual?

EnerSys Alpha Cordex CXC HP Specifications

General IconGeneral
BrandEnerSys
ModelAlpha Cordex CXC HP
CategoryController
LanguageEnglish