EasyManua.ls Logo

EnerSys Alpha Cordex CXC HP - Export Line Power Channels; Sort Exported Line Power Channels; Enter Data into a Line Power Channels File

EnerSys Alpha Cordex CXC HP
279 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cordex®CXCHPControllerSoftwareManual|8-Linepowersystems
8.8.1. Export line power channels
Pre-amble:Alinepowerconnectioninthecontrolleristheshelf,slot,andchanneltogetherwhich
indicatesitsphysicalpositioninthesystem.Thetotalconnectionsonacontrollerforalinepowersystem
isbasedonthemaximumshelves(9)×maximumslots(12)×maximumchannels(4),foragrandtotalof
432totalconnectionsifmodulesareinsertedinallshelvesandslots.
Howtoexport:withalinepowersystemcreatedandmodulesassignedtothesystem,ausercangoto
Systems > Line Power System > Inventory > Line Power Channels andselecttheExport Channel
Details buttontoexportaCSVfilewithallthecurrentlyexistinglinepowerconnectionsavailable.The
exportedconnectionsarebasedonthemodulesacquiredforthelinepowersystem.
Thesections:(1)'SortExportedLinePowerChannels'willhelpsortthelinepowerconnectionsin
MicrosoftExcelasthefilerowswillbeoutoforderandsortingwillmakeiteasiertoenterdata.(2)'Enter
dataintoaLinePowerChannelsFile'willhelppopulatetheexportedCSVfileemptycells.
8.8.2. Sort exported line power channels
Afterexport,ausercanopenthefileinaCSVeditingprogramsuchasMicrosoftExcel.InExcel,
forbetterreadability,itisalwaysrecommendedtosortthedatapresentedastheShelf/Slot/Channel
datacolumnswillbeoutoforder.Aftersortingthedata,ausercanstartenteringtherequireddatain
sequentialorderforwhatchannelbelongstowhichload.
To sort channel data in Microsoft Excel:
1. Highlightalltheavailabledata.
2. SelecttheData tab.
3. SelectSort withintheData tab.
4. IntheSortWindow,addthe"Shelf"columnforSort By usingthedropdownlist.Additionally,verify
theSort On valueis"CellValues"andtheOrder valueis"AtoZ".
5. IntheSortWindow,selecttheAdd Level button.
6. IntheSortWindow,forthenewlevel,addthe"Slot"columnforSort By.
7. SelectOk intheSortWindowtoviewthedatainsequentialorder.
8. Aftersorting,followsection'EnterdataintoaLinePowerChannelsFile'fordetailsonwhattoenter
intotheemptyCSVfilecells.
8.8.3. Enter data into a line power channels file
WhenopeningthelinepowerchannelsCSVfile,therearemultiplecolumnswithheadings.Some
columnsarenottobechanged,somearerecommendedtoenter,andsomearerequiredtobefilledin.
FillintheemptyCSVcellsbasedontheinformationbelow.
0350058-J0 Rev AL Page 121