16. Thermal systems
Thissectionprovidesabriefoverviewofthecomponentsandfunctionsofathermalsystem.
16.1. Introduction
Athermalsystemprovidesinsightintoathermallycontrolledoutdoorcabinet.Itisintendedtobeused
togetherwithoneormoreFlexAir®thermalcontrollers.Athermalsystemenablesactivitiessuchas
loggingsystemtemperaturemeasurementsormonitoringfanspeed,andholdsvariousalarmsrelatedto
anoutdoorcabinet,suchasunsuitableinternaltemperaturealarmsorfanfailurealarms,ifthethermal
controllerhasfans.
16.2. Create a thermal system
To create a new thermal system:
1. GotoSystems > Add or Remove Systems andselecttheCreate System buttontolaunchthe
Create System wizard.
2. IntheCreate System wizard,inthedropdownlistfortheSelect System To Create Step,choose
tocreateaThermal System.
16.3. Thermal system configurations
Thethermalsystemisdesignedwiththeexpectationofa1:1relationshipwithaphysicalcabinet.Ifthe
controllerhandleshardwareinmorethanonecabinet,multiplethermalsystemsshouldbecreated.There
maybesituationswherethereismorethanonethermalcontrollerinagivencabinet.Thisisacceptable.
16.3.1. Single-cabinet setup
Whenthecontrollerhandlesequipmentinonlyonecabinet,asinglethermalsystemshouldbecreated.
WhenathermalcontrollermoduleisconnectedviaCANtothecontroller,bydefault,itisautomatically
addedtothethermalsystem.Ifithasbeensetupformanualconfiguration,thenaddthemodulestothe
thermalsystemmanuallyasdescribedinthemulti-cabinetsetup.
16.3.2. Multi-cabinet setup
Whenthecontrollerhandlesequipmentinmultiplecabinets,athermalsystemshouldbecreatedforeach
physicalcabinet.Whentherearemultiplethermalsystems,itisimportanttogiveeachthermalsystema
customnametodifferentiatethemfromeachother.Thecontrollerdoesnotknowhowever,whichcabinet
thethermalcontrollermodulesareinstalledin.Thereforethemodulesmustbemanuallyaddedtothe
respectivethermalsystems.Todothis:
0350058-J0 Rev AL Page 157

Table of Contents

Other manuals for EnerSys Alpha Cordex CXC HP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EnerSys Alpha Cordex CXC HP and is the answer not in the manual?

EnerSys Alpha Cordex CXC HP Specifications

General IconGeneral
BrandEnerSys
ModelAlpha Cordex CXC HP
CategoryController
LanguageEnglish