RX300 S7
Upgrade and Maintenance Manual 145
Hard disk drives / solid state drives
7.2.4 Replacing a 3.5-inch HDD module
V CAUTION!
●
Only remove an HDD / SSD module during operation if the drive is
not currently being accessed. Observe the indicators for the
corresponding HDD / SSD modules, see "PRIMERGY RX300 S7
Server - Operating manual".
●
Under no circumstances should you remove an HDD / SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
●
All HDD / SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.2.4.1 Required tools
●
Preliminary and concluding steps: tool-less
●
Replacing a 3.5-inch HDD module: tool-less
7.2.4.2 Preliminary steps
Perform the following procedures:
Ê "Opening the rack door" on page 64
Ê "Locating the defective server" on page 56
Ê Locate the defective HDD module as described in section "Local diagnostic
indicators on the front" on page 60.
Customer Replaceable Units (CRU)
Average task duration: 5 minutes