Upgrade and Maintenance Manual 445
Front panel
13.4 Front cage
13.4.1 Replacing the front panel cage
13.4.1.1 Required tools
Preliminary and concluding steps: tool-less
Removing the front LAN connector:
Phillips PH2 / (+) No. 2 screw driver
13.4.1.2 Preliminary steps
Perform the following procedures:
Ê "Disabling BitLocker functionality" on page 85
Ê "Opening the rack door" on page 64
Ê "Locating the defective server" on page 56
Ê "Shutting down the server" on page 65
Ê "Disconnecting power cords" on page 66
Ê "Extending the server out of the rack" on page 69
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page 70.
Ê "Removing the server cover" on page 72
Ê "Removing the air duct" on page 73
Ê "Removing the fan box" on page 183
Field Replaceable Units (FRU)
Average task duration: 10 minutes