Upgrade and Maintenance Manual 177
8 System fan
Basic information
I The fan configuration is redundant. One fan may be faulty. Replace the
fan as soon a possible. During the server is switched on, only one fan
may be removed.
I Additional fans in PSU modules are integral parts of the power supply
units and cannot be replaced separately.
V CAUTION!
Since the system fan is not redundant is has to be replaced immediately
in case of defects or prefailure events.
Safety notes
V CAUTION!
Do not damage or modify internal cables or devices. Doing so may
cause a device failure, fire, or electric shock.
Devices and components inside the server remain hot after
shutdown. After shutting down the server, wait for hot components to
cool down before installing or removing internal options.
Circuit boards and soldered parts of internal options are exposed and
can be damaged by static electricity. Always discharge static build-up
(e.g. by touching a grounded object) before handling electrostatic-
sensitive devices (ESDs).
Do not touch the circuitry on boards or soldered parts. Hold circuit
boards by their metallic areas or edges.
If devices are installed or disassembled using methods other than
those outlined in this chapter, the warranty will be invalidated.
For further information, please refer to chapter "Important
information" on page 43