RX300 S7
Upgrade and Maintenance Manual 227
Expansion cards and backup units
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page 77.
Ê Reconnect all external cables to the replaced expansion card.
Ê "Connecting the server to the power source" on page 81.
Ê In order to configure an expansion card that has been installed or replaced,
the card’s Option ROM has to be enabled in the system board BIOS. If
applicable, proceed as described in section "Enabling Option ROM scan" on
page 97.
Ê "Enabling BitLocker functionality" on page 107.
Ê "Enabling SVOM boot watchdog functionality" on page 101.
Ê Reconfigure your network settings in the operation system according to the
original configuration of the replaced controller (expansion card or onboard).
I Configuration of network settings should be performed by the
customer.
For further information, please refer to section "Note on network
settings recovery" on page 225.
Ê If applicable, restore LAN teaming configurations as described in section
"After replacing / upgrading LAN controllers" on page 112.
9.5 Battery Backup Units (BBU)
The Battery Backup Unit (BBU) backs up the memory contents of the connected
SAS RAID controller in the event of a power failure. The PRIMERGY RX300 S7
server can accommodate up to two BBUs.
9.5.1 Installing a BBU
Upgrade and Repair Units (URU)
Average task duration: 5 minutes