146 Upgrade and Maintenance Manual
RX300 S7
Hard disk drives / solid state drives
Only applicable for removing intact HDD modules:
Ê Before removing a non-defective HDD module, put the drive into "Offline"
mode using your RAID configuration software.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online at http://manuals.ts.fujitsu.com.
7.2.4.3 Removing a 3.5-inch HDD module
Ê "Removing a 3.5-inch HDD module" on page 143
7.2.4.4 Installing a 3.5-inch HDD module
Ê "Installing 3.5-inch HDD modules" on page 140
7.2.4.5 Concluding steps
Perform the following procedures:
Ê Please observe the notes on RAID rebuild in section "Performing a RAID
array rebuild" on page 108.
Ê "Closing the rack door" on page 84
7.3 2.5-inch hard disk drives / solid state drives
7.3.1 Mounting order for 2.5-inch HDDs / SSDs
Maximum configuration: 16x 2.5-inch HDDs / SSDs
General equipping rules
– Solid state drives (SSDs) are always equipped before installing hard disk
drives.
– If only one HDD/SSD module is installed, the HDD/SSD module will be
installed in position 1. Empty bays must be equipped with a dummy module.