RX300 S7
Upgrade and Maintenance Manual 463
System board and components
Ê "Enabling BitLocker functionality" on page 107
14.2.3 Replacing the UFM board
14.2.3.1 Required tools
Preliminary and concluding steps:
combination pliers and flat nose pliers
Replacing the UFM:
Phillips PH0 / (+) No. 0 screw driver
14.2.3.2 Preliminary steps
Perform the following procedures:
Ê "Disabling BitLocker functionality" on page 85
Ê "Disabling SVOM boot watchdog functionality" on page 86
Ê "Opening the rack door" on page 64
Ê "Locating the defective server" on page 56
Ê "Shutting down the server" on page 65
Ê "Disconnecting power cords" on page 66
Ê "Extending the server out of the rack" on page 69
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page 70.
Ê "Removing the server cover" on page 72
Ê "Removing the air duct" on page 73
Field Replaceable Units (FRU)
Average hardware task duration: 10 minutes
Average software task duration: 5 minutes