RX300 S7
Upgrade and Maintenance Manual 159
Hard disk drives / solid state drives
7.3.4.5 Concluding steps
Perform the following procedures:
Ê Please observe the notes on RAID rebuild in section "Performing a RAID
array rebuild" on page 108.
Ê "Closing the rack door" on page 84
7.4 Replacing SAS / SATA HDD / SSD
backplanes
7.4.1 Replacing the 3.5-inch HDD SAS / SATA backplane
7.4.1.1 Required tools
●
Preliminary and concluding steps:
– Phillips PH2 / (+) No. 2 screw driver
●
Replacing the SAS / SATA backplane: tool-less
7.4.1.2 Preliminary steps
Perform the following procedures:
Ê "Opening the rack door" on page 64
Ê "Locating the defective server" on page 56
Ê "Disabling BitLocker functionality" on page 85
Ê "Shutting down the server" on page 65
Ê "Disconnecting power cords" on page 66
Ê Remove all HDD / SSD modules from the server as described in section
"Removing 3.5-inch HDD modules" on page 142.
Field Replaceable Units (FRU)
Average task duration: 10 minutes