64 Upgrade and Maintenance Manual
RX300 S7
Basic hardware procedures
I In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer replaceable unit or if a
service technician needs to be dispatched to replace the part (see
section "Determining the error class" on page 57).
If the system has been powered off to replace a non hot-plug unit, a
system of PRIMERGY diagnostics indicators guides you to the faulty
component.
4.2 Opening the rack door
I The following description only applies to the PRIMECENTER M1 rack.
For further instructions on opening or closing the 19-inch rack, please
refer to the "19-inch Rack for PRIMERGY and RM systems" assembly
guide, available online at http://manuals.ts.fujitsu.com.
The PRIMECENTER M1 rack is equipped with a split front door. The left-hand
door contains an interlocking system that can be locked and opened with a key.
Optionally, a revolving door knob can be mounted for key-less locking. To
unlock and open the rack, proceed as follows:
Ê Insert and turn the key by counter-clockwise by 180 degrees.
If applicable, turn the door knob counter-clockwise by 180 degrees.
Ê Open the left-hand door first, then the right-hand door.
I For further information, refer to the "PRIMECENTER Rack System"
assembly guide available online at http://manuals.ts.fujitsu.com .
M Standby power yellow on voltage ok
N iRMC
green
flashing
iRMC S3 ok
O fans orange on Fan faulty
P battery orange on battery faulty
Indicator Status Description