220 Upgrade and Maintenance Manual
RX300 S7
Expansion cards and backup units
Ê "Enabling SVOM boot watchdog functionality" on page 101.
Ê "Enabling BitLocker functionality" on page 107.
Ê If applicable, restore LAN teaming configurations as described in section
"After replacing / upgrading LAN controllers" on page 112.
9.4.1.7 Concluding software tasks
If the Modular LAN controller is to be used as a shared LAN interface, please
proceed as follows:
Ê Ensure that the NCSI cable has been connected to the Modular LAN
controller and the system board as described in sections "Connecting the
NCSI sideband cable to the Modular LAN controller" on page 215 and
"Connecting the NCSI sideband cable to the system board" on page 218.
Ê Enter the BIOS.
Ê Select the Server Mgmt menu.
Ê Under iRMC LAN Parameters Configuration set the Management LAN Port
setting to Shared 2.
Ê Save your changes and exit the BIOS.
I For detailed information on how to access the BIOS and modify settings,
refer to the "System Board D2939 BIOS Setup Utility" reference manual.
The document is available online at http://manuals.ts.fujitsu.com
(http://jp.fujitsu.com/platform/server/primergy/manual/ for the Japanese
market).