484 Upgrade and Maintenance Manual
RX300 S7
System board and components
14.4.1.4 Concluding steps
Perform the following procedures:
Ê "Installing the air duct" on page 74
Ê "Mounting the server cover" on page 76
Ê "Sliding the server into the rack" on page 80
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page 77.
Ê "Connecting the server to the power source" on page 81
Ê "Enabling BitLocker functionality" on page 107.
14.4.2 Removing the onboard SAS enabling key
14.4.2.1 Required tools
●
Preliminary and concluding steps: tool-less
●
Removing the onboard SAS enabling key: tool-less
14.4.2.2 Preliminary steps
Perform the following procedures:
Ê "Disabling BitLocker functionality" on page 85
Ê "Locating the defective server" on page 56
Ê "Shutting down the server" on page 65
Ê "Disconnecting power cords" on page 66
Ê "Extending the server out of the rack" on page 69
Field Replaceable Units (FRU)
Average task duration: 5 minutes