Upgrade and Maintenance Manual 69
Basic hardware procedures
4.5.2 Extending the server out of the rack
Figure 11: Extending the server out of the rack
Ê Shut down the server and remove external cables as described in section
"Preliminary steps" on page 68.
Ê If you are not using a cable mounting arm (CMA kit), ensure that the rear
cables are long enough not to be strained or damaged when extending the
server out of the rack.
Ê Fold down the two quick release levers on the rack mounting frame (1) and
pull the server out of the rack until it locks in place (2).
V CAUTION!
Do not use the extended server as a surface on which to put things or as
a work surface, and strictly avoid leaning on or against it.