280 Upgrade and Maintenance Manual
RX300 S7
Main memory
– In order to satisfy cooling requirements, populate memory channels on
alternating sides of the processor:
10.2 Installing memory modules
10.2.1 Required tools
●
Preliminary and concluding steps: tool-less
●
Installing memory modules: tool-less
10.2.2 Preliminary steps
Perform the following procedures:
Ê "Disabling BitLocker functionality" on page 85
Ê "Disabling SVOM boot watchdog functionality" on page 86
Ê "Shutting down the server" on page 65
Ê "Disconnecting power cords" on page 66
Ê "Extending the server out of the rack" on page 69
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page 70.
Order CPU 1 CPU 2
1 Channel A Channel E
2 Channel C Channel G
3 Channel B Channel F
4 Channel D Channel H
Upgrade and Repair Units (URU)
Average task duration: 5 minutes