494 Upgrade and Maintenance Manual
RX300 S7
System board and components
Ensure not to damage the EMI springs to comply with applicable
EMC regulations and satisfy cooling requirements and fire
protection measures.
Ê At a slight angle, lower the system board into the chassis.
Ê Carefully shift the system board towards the server rear until the plug shells
engage with the cut-outs in the connector panel (1).
Ê Lower the system board onto the centering bolts (C).
Ensure that the system board is properly seated on both centering bolts.
Figure 310: Securing the system board
Ê Secure the system board with 13 screws (M3 x 6 mm, C26192-Y10-C68)
(see circles).
I If you want to install a SAS RAID controller, do not insert the screw
markt with (1).
I Screw torque: 0.6 Nm (not applicable for the Japanese market)
Tighten the screws in a cross diagonal pattern.
Ê Verify the settings on the new system board (jumpers).