RX300 S7
Upgrade and Maintenance Manual 95
Basic software procedures
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL) using the ServerView Operations Manager
(see also section "Viewing and clearing the System Event Log (SEL)" on
page 104).
After replacing the system board
Ê Check the SEL log files as described in section "Viewing and clearing the
System Event Log (SEL)" on page 104 to verify whether the backup data on
the Chassis ID EPROM has been restored to the system board:
Chassis IDPROM: Restore successful
After replacing the Chassis ID EPROM
I In case of the PRIMERGY RX300 S7 server, the Chassis ID EPROM is
integrated on the front panel board.
Ê Check the SEL log files as described in section "Viewing and clearing the
System Event Log (SEL)" on page 104 to verify whether a backup copy of
the system board settings has been transferred to the Chassis ID EPROM:
Chassis IDPROM: Backup successful