TX150 S8 / TX200 S7
Upgrade and Maintenance Manual 145
Hard disk drives / solid state drives
7.2.4 Removing 2.5-inch HDD / SSD modules
7.2.4.1 Preliminary steps
Ê If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V CAUTION!
All data on all HDDs / SSDs in the array will be lost! Be sure to back
up your data before deleting a RAID array.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools: tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
V CAUTION!
Removing an operational HDD module will result
in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section "Performing a RAID array
rebuild" on page 101.