TX150 S8 / TX200 S7
Upgrade and Maintenance Manual 255
11.2 Installing processors
V CAUTION!
Processors are extremely sensitive to electrostatic discharge and must
be handled with care. After a processor has been removed from its
protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.
11.2.1 Preliminary steps
Ê "Disabling or suspending BitLocker functionality" on page 79
Ê "Disabling SVOM boot watchdog functionality" on page 80
Ê "Shutting down the server" on page 50
Ê "Disconnecting the server from the mains" on page 50
Ê "Getting access to the component" on page 51
11.2.2 Installing a processor
I This description applies to the following procedures:
– Installing the second processor in a single-processor configuration
– Transfering a processor after replacing the system board (see section
"Replacing the system board" on page 375)
Upgrade and Repair Unit
(URU)
Hardware: 15 minutes
Software: 5 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver