402 Upgrade and Maintenance Manual
TX150 S8 / TX200 S7
Converting a tower model to a rack model
15.3 Concluding steps
Ê "Installing the top cover" on page 66
Figure 309: Attaching the caution label
Ê Attach the caution label on the left front edge of the top cover as shown.
Ê Mount the support bracket and rack mounting rails in the rack as described
in the "Rack Mounting Kit - RMK-F2 Drop-In" Mounting Instructions.
I The document is available online or from the ServerView Suite DVD
2 supplied with your PRIMERGY server. The printed poster is
contained in the rack mounting kit.
Ê Mount the server in the rack as described in section "Mounting the server in
the rack" on page 67.
Ê Reconnect all external cables.
Ê "Connecting the server to the mains" on page 74
Ê "Switching on the server" on page 75
Ê Update your server’s chassis information on the Chassis ID EPROM
integrated into the front panel board. For further information on how to obtain
and use the ChassisId_Prom Tool, refer to section "Using the Chassis ID
Prom Tool" on page 103.
Ê Change the chassis model setting to "rack server" as described in section
"Specifying the chassis model" on page 105".