168 Upgrade and Maintenance Manual
TX150 S8 / TX200 S7
Hard disk drives / solid state drives
Ê Slide the intrusion switch holder under the front chassis rim as far as it will
go (2).
Figure 96: Installing the 3.5-inch HDD bay top cover (C)
Ê Secure the HDD bay top cover to the chassis with five screws (see blue
arrows).
Ê Secure the intrusion switch holder on the HDD bay top cover with one screw
(see orange arrow).
Ê Connect the cables to the SAS backplane (see figure 88).
7.3.7.4 Concluding steps
Ê "Installing the system fan holder" on page 77
Ê "Reassembling" on page 64
Ê "Connecting the server to the mains" on page 74
Ê "Switching on the server" on page 75
Ê "Installing a 3.5-inch HDD module" on page 157 and "Installing a 3.5-inch
HDD dummy module" on page 161.
I For detailed information on HDD mounting order, refer to section "3.5-
inch HDD configurations" on page 152.