Page #266 background imageLoading...
Page #266 background image
266 Upgrade and Maintenance Manual
TX150 S8 / TX200 S7
Processors
Ê Remove the desired processor as described in section "Removing a
processor" on page 260.
Ê Install the new processor as described in section "Installing a processor" on
page 255.
Ê In case of transferring a processor install the protective cover to the
defective system board as described in section "Installing the protective
cover" on page 263.
11.4.3 Concluding steps
Ê "Installing processor heat sinks" on page 268
Ê "Reassembling" on page 64
Ê "Connecting the server to the mains" on page 74
I If Global Error LED is flashing with error message CPU has been
changed on display after the system is powered on, please follow the
procedure below.
Ê Restart your server.
Ê As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
If a password is assigned, enter the password and press [Enter].
Ê Select the Save & Exit menu.
Ê Select Save Changes and Exit or Save Changes and Reset.
Ê Verify that the LED stops flashing. This is only information regarding
to the change of CPU configuration. There is no technical problem.
Ê "Updating or recovering the system board BIOS and iRMC" on page 87 (if
applicable)
Ê "Switching on the server" on page 75
Ê "Enabling SVOM boot watchdog functionality" on page 94
Ê "Enabling BitLocker functionality" on page 100

Table of Contents

Other manuals for Fujitsu PRIMERGY TX150 S8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX150 S8 and is the answer not in the manual?

Fujitsu PRIMERGY TX150 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX150 S8
CategoryServer
LanguageEnglish

Related product manuals