EasyManua.ls Logo

Juniper T640 - Maintaining the T640 Control Boards

Juniper T640
580 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T640 RE-C1800 LEDs on page 43
Troubleshooting the T640 Host Subsystem on page 472
Maintaining the T640 Control Boards
Purpose For optimum router performance, verify the condition of the routers control boards.
Action On a regular basis:
Check the LEDs on the control board faceplate. During normal operations:
The green OK LED on the control board faceplate is lit.
The green host subsystem OK LED on the craft interface is lit.
The red host subsystem FAIL LED on the craft interface is not lit.
The yellow FAIL LED on the control board faceplate is not lit.
Issue the show chassis environment cb command to check the status of the control
boards. The output is similar to the following:
user@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 29 degrees C / 84 degrees F
Power:
1.8 V 1809 mV
2.5 V 2496 mV
3.3 V 3295 mV
4.6 V 4687 mV
5.0 V 5042 mV
12.0 V 11985 mV
3.3 V bias 3277 mV
8.0 V bias 7472 mV
GBUS Revision 40
FPGA Revision 7
For further description of the output from the commands, seeshow chassis environment
cb.
Related
Documentation
T640 Control Boards Description
T640 Standard Control Boards LEDs on page 64
T640 T Series Control Boards (T-CBs) LEDs on page 66
T640 LCC-CB LEDs on page 62
Troubleshooting the T640 Host Subsystem on page 472
Troubleshooting the T640 Control Board on page 473
449Copyright © 2017, Juniper Networks, Inc.
Chapter 32: Maintaining Components

Table of Contents

Other manuals for Juniper T640

Related product manuals