Table 98: FPC Alarm Messages
CLI MessageCraft Interface MessageAlarm Type
FPC fpc-number has unreachable destinationsFPC fpc-number unreachable PFEs detectedMajor
Related
Documentation
T640 Craft Interface Description on page 22•
• T640 FPC Description on page 67
• Replacing a T640 FPC on page 333
Troubleshooting the T640 PICs
Problem Description: The PICs are not functioning normally.
Solution To troubleshoot the PICs:
• To check the status of each port on a PIC, look at the LED located on the PIC faceplate.
For information about the meaning of LED states on different PICs, see the T640 Core
Router Interface Module Reference.
• To check the status of a PIC, issue the following CLI command. The PIC slots in the
FPC are numbered from 0 through 3, top to bottom:
user@host> show chassis fpc pic-status
Slot 0 Online E-FPC Type 3
PIC 0 Online 1x 10GE(LAN),DWDM
PIC 2 Present 1x OC-192 SONET XFP- Hardware Error
PIC 3 Online 1x 10GE(LAN),XENPAK
Slot 2 Online E2-FPC Type 2
PIC 0 Online 1x OC-48 SONET, SMIR
PIC 1 Online 2x OC-12 ATM-II IQ, MM
PIC 2 Online 8x 1GE(LAN), IQ2
Slot 3 Online FPC Type 3
PIC 0 Online 1x 10GE(LAN),XENPAK
PIC 1 Online 1x 10GE(LAN),XENPAK
PIC 2 Online 8x 1GE(TYPE3), IQ2
PIC 3 Online 8x 1GE(TYPE3), IQ2
Slot 4 Online FPC Type 4
PIC 0 Online 4x OC-192 SONET XFP
Slot 6 Online FPC Type 3
PIC 0 Online 4x OC-48 SONET
PIC 1 Online 1x Tunnel
Slot 7 Online FPC Type 4
PIC 0 Online 1x OC-768 SONET SR
For further description of the output from the command, see show chassis environment
fpc.
475Copyright © 2017, Juniper Networks, Inc.
Chapter 33: Troubleshooting Components