WARNING: The intrabuilding ports of the equipment or subassembly are
suitable for connection to intrabuilding or unexposed wiring or cabling only.
The intrabuilding ports of the equipment or subassembly MUST NOT be
metallically connected to interfaces that connectto the Outside Plant (OSP)
or its wiring. These interfaces are designed for use as intrabuilding interfaces
only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 4) and
require isolation from the exposed OSP cabling. The addition of primary
protectors is not sufficient protection in order to connect these interfaces
metallically to OSP wiring.
Related
Documentation
• General Electrical Safety Guidelines and Electrical Codes for Juniper Networks Devices
539Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Electrical Safety Guidelines and Warnings