1240 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
34 :WAVeform Commands
If the :WAVeform:FORMat is WORD (see page 1245) is WORD, every other data
byte will be 0. The setting of :WAVeform:BYTeorder (see page 1241) controls
which byte is 0.
If a digital channel is not displayed, its bit value in the pod data byte is not defined.
Digital Channel BUS Data Format
Digital channel BUS definitions can include any or all of the digital channels.
Therefore, data is always returned as 16-bit values. :BUS commands (see
page 279) are used to select the digital channels for a bus.
Reporting the Setup
The following is a sample response from the :WAVeform? query. In this case, the
query was issued following a *RST command.
:WAV:UNS 1;VIEW MAIN;BYT MSBF;FORM BYTE;POIN +1000;SOUR CHAN1;SOUR:SUBS
NONE