2JZ/2JX/2JV/2H7-1
2-3-46
YC13 1 +24V2 O 24 V DC 24 V DC power to MCL
Connected
to the mid-
dle clutch
and registra-
tion clutch
(25/25, 30/
30 ppm
model)
2 ROL UP2 CLT
REM
O 0/24 V DC MCL: On/Off
3 +24V2 O 24 V DC 24 V DC power to RCL
4 REG UP1 CLT
REM
O 0/24 V DC RCL: On/Off
YC14 A1 LOOP SENS I Analog LS: On/Off
Connected
to the loop
sensor,
feedshift
switch, JAM
LED PWB 1/
2, loop fan
motor, paper
conveying
fan motor 1/
2, left cover
1 switch,
duplex
switch and
duplex
motor (40/
40, 50/40
ppm model)
A2 GND - - Ground
A3 +5V1 O 5 V DC 5 V DC power to LS
A4 GND - - Not used
A5 BELT JAM - - Not used
A6 +5V1 - - Not used
A7 GND - - Ground
A8 DU ENTER JAM I 0/3.3 V DC FSSW: On/Off
A9 +5V1 O 5 V DC 5 V DC power to FSSW
A10 +5V1 O 5 V DC 5 V DC power to JLEDPWB2
A11 JAM2 LED O 0/5 V DC (pulse) LED emitter signal
A12 +5V1 O 5 V DC 5 V DC power to JLEDPWB1
A13 JAM1 LED O 0/5 V DC (pulse) LED emitter signal
A14 SENSOR FAN O 0/24 V DC LFM: On/Off
A15 +24V2 O 24 V DC 24 V DC power to LFM
B1 NC - - Not used
B2 NC - - Not used
B3 COV FAN1 REM O 0/24 V DC PCFM1: On/Off
B4 +24V2 O 24 V DC 24 V DC power to PCFM1
B5 COV FAN2 REM O 0/24 V DC PCFM2: On/Off
B6 +24V2 O 24 V DC 24 V DC power to PCFM2
B7 DU OPEN I 0/3.3 V DC LC1SW: On/Off
B8 GND - - Ground
B9 GND - - Ground
B10 DU JAM I 0/3.3 V DC DUSW: On/Off
B11 +5V1 O 5 V DC 5 V DC power to DUSW
B12 DU AN O 0/24 V DC (pulse) DUM drive control signal
B13 DU BN O 0/24 V DC (pulse) DUM drive control signal
B14 DU AP O 0/24 V DC (pulse) DUM drive control signal
B15 DU BP O 0/24 V DC (pulse) DUM drive control signal
Connector Pin No. Signal I/O Voltage Description