2JZ/2JX/2JV/2H7-1
1-2-22
36. Connect the connector of the key counter
signal cable to the connector of the key
counter wire.
37. Fit the key counter cover with the key
counter socket assembly inserted to the key
counter cover retainer on the machine using
the M4 x 30 screw.
38. Refit the scanner right cover.
39. Insert the key counter into the key counter
socket assembly.
Figure 1-2-31
40. Turn the main power switch on and enter the
maintenance mode.
41. Run maintenance item U204 and select
"Key-Counter".
42. Exit the maintenance mode.
43. Check that the message requesting the key
counter to be inserted is displayed on the
touch panel when the key counter is pulled
out.
44. Check that the counter counts up as copies
are made.
Key counter wire
(302H746930)
Key counter wire
(302H746930)
Connector
Connector
Connector
M4 x 30 screw
(B1B54300)
Key counter cover
Key counter
cover retainer
(302GR03010)
Key counter
signal cable

Table of Contents