2JZ/2JX/2JV/2H7-1
1-3-3
Optical U071 Adjusting the DP scanning timing 0/0/0/0/0/0
U072 Adjusting the DP center line 0/0/0
U073 Checking the scanner operation -
U080 Setting the economy mode 60/60
U081 Adjusting the correct exposure 0/0/0/0/0/0
U087 Setting DP reading position modification operation 145/145/145
U089 Outputting the MIP-PG pattern -
U091 Setting the white line correction 112/112/112/75/0
U093 Adjusting the exposure density gradient
TEXT
MIXED
OTHER
FAX TEXT
FAX PHOTO
0/0/0/0
0/0/0/0
0/0/0/0
0/0
0/0
U099 Adjusting original size detection 40/30/20/40/30/20/40/30/20/
19/19/19/150
50/50/50/50/50/50/50/50/50/
49/49/49/150 (when DP is installed
High
voltage
U100 Adjusting main high voltage
Adjust MC AC Bias
AC Auto Adjustment
Set DC1
Adjust DC2
Adjust DC2(B/W)
Set Charger Freq
150/150/150/150/150
ON
-
0/0/0/0/0/0/0/0
0
31449/31449
U101 Setting the voltage for the primary transfer
Normal (Full M) 95 105
Normal (Half M) 75 78
Normal (B/W M) 105
Add Color (C) 5
Add Color (Y) 5
Add Color (K) 15 20
Surround Correct 0
U106 Setting the voltage for the secondary transfer
Light/Normal 1 Full Front 150/120/90 160/140/110
Normal 2/3 Full Front 150/120/90 180/150/130
Light/Normal 1 Full Back 150/110/65 180/120/65
Normal 2/3 Full Back 150/110/70 150/130/100
Light Normal1(F)Front BW 150/120/90 180/140/130
Normal2/3(F)Front BW 150/120/90 180/140/130
Light/Normal1(F)Back BW 150/110/65 160/130/90
Normal2/3(F)Back BW 150/110/70 160/130/90
Heavy 1 - 3 (H)Front 150/90/65 150/90/80
Heavy 1 - 3 (H)Back 110/80/45 13/100/60
OHP 97/44 123/51
Bias 189/189/189/34/34/34
Section
Item
No.
Content of maintenance item
Initial setting*
25/25,30/30 ppm 40/40 ppm 50/40 ppm
*Initial setting for executing U020, *1: The item initialized for executing U021