2JZ/2JX/2JV/2H7-1
1-3-4
High
voltage
U107 Setting the transfer cleaning voltage
Belt Clean A(F) 70/70/70 83/83/83
Belt Clean A(H) 50/50/50 62/62/62
Belt Clean B 140/105/150 150/120/150
Belt Clean A(BW) 120/120/120
U108 Setting separation shift bias
Set Output Value 85/60/52/60/8/26
Set Output Value B/W - 85/60/
52/60
Set Timing -190/0/110 -200/0/110
U109 Checking the drum type -
U110 Checking the drum count -
U111 Checking the drum drive time -
U117 Checking the drum number -
U118 Displaying the drum history -
U119 Setting the drum -
U122 Checking the transfer belt unit number -
U123 Displaying the transfer belt unit history -
U127 Checking the transfer count -
U128 Setting transfer high-voltage timing -54/-54/10
Developing U130 Initial setting for the developing unit -
U131 Adjusting the toner sensor control voltage
Manual Adjustment
Auto Adjustment
Set Operation Mode
116/116/116/116
-
Automatic adjustment
U132 Replenishing toner forcibly -
U135 Checking toner motor operation -
U136 Setting toner near end detection 2/2
*1
U139 Displaying the temperature and humidity outside the
machine
-
U140 Displaying developing bias -
Dev Roll2 DC 80/80/80/80/87
93/93/93/93/101
Dev Roll2 AC 174/174/174/174/174
Dev Roll1 Normal 162/162/162/162/162
Roll1 Normal Int 85/85/85/85/89
Roll1 ON/OFF KC 0/0/0/0/0/0/0/0/0/0
DEV Roll Freq 858/858/858/858/858
DEV Roll Duty 373/373/373/373/313
Dev Roll2 DC Interval 80/80/80/80
93/93/93/93
Dev Roll1 Freq Interval 858/858/858/858
Dev Roll1 Duty Interval 373/373/373/373
Section
Item
No.
Content of maintenance item
Initial setting*
25/25,30/30 ppm 40/40 ppm 50/40 ppm
*Initial setting for executing U020, *1: The item initialized for executing U021