Operator panel door assembly switch failure service check
Action Yes No
Step 1
Check the fuser wiper cover assembly for missing parts or damage,
such as cracks. If necessary, replace the fuser wiper cover
assembly. See
“Fuser wiper cover assembly removal” on
page 375.
Does the problem remain?
Go to step 2. The problem is
solved.
Step 2
Remove all media present in the media path.
Does the problem remain?
Go to step 3. The problem is
solved.
Step 3
Close the operator panel assembly door.
Does the problem remain?
Go to step 4. The problem is
solved.
Step 4
Check the operator panel assembly door for damage. If necessary,
replace the operator panel assembly door. Go to
“Operator panel
door assembly removal (models X651, X652, X654,X656)” on
page 345.
Does the problem remain?
Go to step 5. The problem is
solved.
Step 5
Check the interlock switch (left operator panel hinge) for damage.
If necessary, replace the interlock switch.
Does the problem remain?
Go to step 6. The problem is
solved.
Step 6
Connect all the cables on the system card properly.
Does the problem remain?
Contact the next
level of support.
The problem is
solved.
7462
Diagnostic information
81