Signal Routing and System Configuration
R&S
®
SMW200A
189User Manual 1175.6632.02 ─ 30
The graphic depicts the main phases for connecting and configuring the R&S SMW
and the external instruments. This illustration is a simplified diagram that highlights the
configuration stages performed in the "System Configuration" dialog.
For relevant information on the configuration of the baseband source signal or using
the fading simulator and the AWGN generator, see:
Chapter 5, "Configuring the Internal Baseband Source", on page 216
Chapter 4.6, "Digital Baseband Input Settings", on page 158
user manual "Fading Simulator"
Figure 4-19: General configuration stages and the steps performed in the System Configuration dia-
log
The illustration depicts the steps in general and is intended to explain the configuration
in principle.
For a step-by-step description of how to perform the different steps, see:
Finding Out the Suitable Configuration for Your Test Situation............................. 189
How to Find Out where the Input/Output Interface Is Located..............................190
How to Define the MIMO Scenario........................................................................191
How to Route the I/Q Streams to the Output Interfaces........................................193
How to Cable the Instruments in MIMO Test Setups............................................ 194
How to Connect and Configure External Instruments...........................................195
How to Generate a 2x8 MIMO Signal for BS Tests...............................................204
How to Generate a 8x8 MIMO Signal with Two R&S SMW.................................. 206
How to Connect an R&S
®
CMW500 for Fading Applications.................................210
How to Apply an External Digital Baseband Signal...............................................211
How to Connect an R&S EX-IQ-BOX....................................................................214
4.9.1 Finding Out the Suitable Configuration for Your Test Situation
For conceptual information on the workflow, refer to "General workflow for finding out
the suitable system configuration for a current use case" on page 107.
1. Select a system configuration form the test cases listed in Table 4-1.
The table provides a cross-reference between a test scenario and the required
configuration.
2. Select "Taskbar > System Configuration > Fading/Baseband Settings":
Follow the instructions in "To simulate complex MxN MIMO scenarios using the
"Fading and Baseband Configuration" settings" on page 191.
How to Connect External Instruments and Configure the Signal Flow