Remote Control Commands
R&S
®
SMW200A
1139User Manual 1175.6632.02 ─ 30
Parameters:
<WbState> 0 | 1 | OFF | ON
*RST: 0
*RST: 0 (R&S SMW-B10) / 1 (R&S SMW-B9)
Example:
IQ:WBST 1
Switches to wideband mode.
Manual operation: See "I/Q Wideband" on page 452
14.19.10 SOURce:IQ:OUTPut Subsystem
The SOURce:IQ:OUTPut subsystem contains the commands for configuring analog
and digital I/Q output signals.
For information about the required options, see:
●
Chapter 4.7, "I/Q Digital Output Settings", on page 172
●
Chapter 4.8, "I/Q Analog Output Settings", on page 182
For information on the connector and interfaces the analog and digital I/Q signals are
output at, see:
Table 4-4.
14.19.10.1 SOURce:IQ:OUTPut:ANALog Commands
This section describes the commands of the output of an analog I/Q signal.
Example: Enabling and configuring the analog output
SCONfiguration:OUTPut:MAPPing:IQOutput1:STReam1:STATe 1
SOURce1:IQ:OUTPut:ANALog:PRESet
SOURce1:IQ:OUTPut:ANALog:TYPE DIFF
SOURce1:IQ:OUTPut:ANALog:MODE VAR
SOURce1:IQ:OUTPut:LEVel 2
SOURce1:IQ:OUTPut:ANALog:BIAS:COUPling:STATe 1
SOURce1:IQ:OUTPut:ANALog:BIAS:I 1
SOURce1:IQ:OUTPut:ANALog:BIAS:Q?
// 1
SOURce1:IQ:OUTPut:ANALog:OFFSet:I 2
SOURce1:IQ:OUTPut:ANALog:OFFSet:Q 2.5
SOURce1:IQ:OUTPut:ANALog:STATe 1
[:SOURce<hw>]:IQ:OUTPut:ANALog:STATe................................................................... 1140
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:PRESet...............................................................1140
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:SETTing:CATalog?............................................... 1140
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:SETTing:STORe.................................................. 1141
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:SETTing:LOAD.................................................... 1141
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:SETTing:DELete.................................................. 1141
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:TYPE.................................................................. 1141
SOURce Subsystem