:SCONfiguration:OUTPut:MAPPing:STReam<st>:FOFFset <SmFreqOffset>
Option: R&S SMW-B9 - supported if "Signal Outputs = Analog Only"
Sets an absolute frequency offset.
Thus, the streams routed to the RF, I/Q Out and BBMM connectors are shifted in the
frequency domain.
Parameters:
<SmFreqOffset> float
Range: depends on the installed options, e.g. -60E6 to
+60E6 (base unit)
Increment: 0.01
*RST: 0
Value range depends also on the system confugration mode and
signal outputs. For details, see data sheet.
Example: See Example "Distributing the I/Q streams to the output connec-
tors" on page 904.
Manual operation: See "f
offset
, MHz" on page 133
:SCONfiguration:OUTPut:MAPPing:STReam<st>:POFFset <SmPhasOffset>
Option: R&S SMW-B9 - supported if "Signal Outputs = Analog Only"
Sets the phase offset of the corresponding stream.
Parameters:
<SmPhasOffset> float
Range: -999.99 to 999.99
Increment: 0.01
*RST: 0
Example: See Example "Distributing the I/Q streams to the output connec-
tors" on page 904.
Manual operation: See "Phase Offset" on page 134
14.18.4 External RF and I/Q Instruments
The following commands configure external RF and I/Q instruments.