Configuring the Internal Baseband Source
R&S
®
SMW200A
398User Manual 1175.6632.02 ─ 30
6. Select "ARB: Multi Carrier > Carrier Graph" to visualize the configuration.
7. Select "ARB: Multi Carrier > General > Output Settings > Output File" and enter the
name of the output file, for example 4x5MHz_3gpp_1_16.
8. To trigger signal calculation and to load the waveform in the ARB generator, select
"ARB: Multi Carrier > General > Create/Create and Load" function.
9. Select "ARB > General > Load Waveform".
Confirm that you loaded the generated multi-carrier waveform.
10. Select "ARB > State > On" to enable the ARB generator.
5.12 Generating Multi-Carrier Continuous Wave Signal
The multi-carrier continuous wave (MCCW) is a firmware option that enables the
R&S SMW to calculate up to 160001 continuous wave signals.
Generating Multi-Carrier Continuous Wave Signal