Multi-Instrument Setups
R&S
®
SMW200A
668User Manual 1175.6632.02 ─ 30
10.5.3 Control of Connected R&S SGT
Up to 6 R&S SGT instruments can be connected to the R&S SMW. As with all external
instruments, you find R&S SGT-related information like the connection status and the
used RF level and frequency values in the External RF and I/Q dialog. This dialog pro-
vides also additional short information on each of the connected instruments.
Settings related to the output signal are grouped in the I/Q Digital dialog.
10.5.4 Control of Connected R&S SZU
If SZU is connected to the R&S SMW, the R&S SMW block diagram changes and
resembles the signal routing. The analog I/Q output signal is firmly routed to the R&S
SZU. The I/Q modulator block visualizes the I/Q modulator of the R&S SZU. The rout-
ing is fixed. You can only swap the streams (A and B) at the RF outputs of use the dif-
ferential I/Q outputs instead of the default single-ended output.
1 2 3 4 5
6
7
9
10
8
Figure 10-12: Block diagram of wideband baseband R&S
SMW (R&S
SMW-B9) with connected R&S
SZU
1 = RF frequency at the R&S SZU RF output
2, 5 = RF frequency and level settings at the second R&S SMW RF output
3 = I/Q modulator of the R&S SZU
4 = RF level, nominal level at the R&S SZU RF output (regulated level)
6 = R&S SZU, indicated as waveguide port icon, label and the serial number
6, 7 = Access to the R&S SZU RF settings (RF block or icon)
Control and Operation of External Instruments