Configuring the RF Signal
R&S
®
SMW200A
581User Manual 1175.6632.02 ─ 30
[:SOURce<hw>]:CORRection:DEXChange:AFILe:EXTension on page 1120
[:SOURce<hw>]:CORRection:DEXChange:AFILe:SEParator:DECimal
on page 1121
[:SOURce<hw>]:CORRection:DEXChange:AFILe:SEParator:COLumn
on page 1120
Select (ASCII) Source/Select (ASCII) Destination
In "Mode > Import", access the file select dialog that provides standard file handling
functions.
Where:
●
"Select ASCII Source": defines the file to be loaded (imported)
●
"Select ASCII Destination": selects the filename under that the loaded file is saved
Remote command:
[:SOURce<hw>]:LIST:DEXChange:AFILe:CATalog? on page 1177
[:SOURce<hw>]:LIST:DEXChange:AFILe:SELect on page 1178
[:SOURce<hw>]:CORRection:DEXChange:AFILe:CATalog? on page 1120
[:SOURce<hw>]:CORRection:DEXChange:AFILe:SELect on page 1120
Select Source/Select ASCII Destination
In "Mode > Export", access the file select dialog that provides standard file handling
functions.
Where:
●
"Select Source": selects the file to be exported
●
"Select ASCII Destination": defines the filename and the file path for the exported
file
Remote command:
[:SOURce<hw>]:LIST:DEXChange:SELect on page 1179
[:SOURce<hw>]:CORRection:DEXChange:SELect on page 1121
Import / Export
Imports or exports the selected data list file, depending on the current mode.
Remote command:
[:SOURce<hw>]:LIST:DEXChange:EXECute on page 1177
[:SOURce<hw>]:CORRection:DEXChange:EXECute on page 1121
8.9.4 Using Power Sensors
The R&S SMW works with most of the R&S NRP power sensors and thus supports
various application tasks. Using power sensors, you can for example determine attenu-
ation characteristics of downstream equipment or cables. You can use the measured
values to compensate the losses with internal control functions or with an external con-
trol circuit in real time.
R&S NRP sensors are highly accurate standalone measuring devices, suitable for a
wide range of applications. The devices communicate directly with the signal genera-
tor, calculate the average or peak power internally, include S-parameter correction and
return the measurement results to the generator.
Improving Level Performance