EasyManua.ls Logo

Rohde & Schwarz R&S SMW200A - Significant Parameters and Functions

Rohde & Schwarz R&S SMW200A
1403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the RF Signal
R&S
®
SMW200A
505User Manual 1175.6632.02 ─ 30
Lists are saved as files with user-definable filename and the predefined file exten-
sion *.lsw. To load a saved file, use the "File Manager".
(See Chapter 11.8, "Using the File Manager", on page 690)
Lists can be exported, too. For example, to exchange configuration between instru-
ments or to modify the file content with an external program and reload them again.
Externally
Create a list file as a CSV file with Microsoft Excel, with a Notepad or a similar tool
and save it with the predefined extension. Transfer the file to and load it into the
instrument.
Dwell time mode
You can choose whether you want to use different dwell times or a fixed value for all
steps in the list mode:
"From List"
This mode uses the values from the data table.
See Edit List Mode Data
"Global"
This mode processes the list with a fixed time interval you can set with Global
Dwell Time.
List processing mode
The R&S SMW generates signals from list files in two modes, "Live" and "Learned
(Frozen RF Settings)". These modes differ in terms of signal quality, signal processing
and switching time.
For details, see:
"Learn List Mode Data list processing mode" on page 507
"Live list processing mode" on page 507
8.7.4 Significant Parameters and Functions
This section provides some basic parameters, settings and functions that affect the
operating modes CW, list and sweep, that means at all frequency and level transitions
of the RF signal.
Dwell time
Dwell time is the length of time that elapses from the beginning until the end of a step
in list or sweep mode.
Varying the RF Signal in List or Sweep Mode

Table of Contents