Multi-Instrument Setups
R&S
®
SMW200A
669User Manual 1175.6632.02 ─ 30
8 = Active I/Q analog output, firmly routed to the R&S SZU; the example uses differential output signal
9 = I/Q analog B is disabled, because the differential output of the first path is used
10 = R&S SMW RF settings
The R&S SMW controls the R&S SZU as it is its embedded unit. You access the R&S
SZU settings directly from the R&S SMW block diagram. The access is identical to the
access of the R&S SMW RF settings but the list shows only the supported settings.
For example:
To access the R&S SZU RF settings, select the R&S SZU icon.
To access the I/Q modulator settings of the R&S SZU, select the "I/Q Mod" block.
The R&S SMW RF settings are dedicated to the R&S SZU. The corresponding RF
output cannot be used for other application, like, for example, LO coupling.
As with other downstream instruments, the frequency and level indications in the
R&S SMW status bar show the R&S SZU values. Parameters like the frequency and
level offset, level limits, delta phase or RF output state affect the RF output of the R&S
SZU.
The remote commands required to define the R&S SZU settings are the same as the
R&S SMW commands, so that you can reuse your SCPI scripts. Note the changes in
the value ranges and the commands usage listed in chapter "Remote Control" in the
description SZU100A Getting Started.
For step-by-step description, see:
Chapter 4.9.6, "How to Connect and Configure External Instruments", on page 195
10.5.5 Further Information
For step-by-step descriptions, see:
Chapter 4.9, "How to Connect External Instruments and Configure the Signal
Flow", on page 188
For information on the possible scenarios and test setups, see:
Chapter 4.1.2, "From a Test Scenario to the Required System Configuration",
on page 108
For description of the settings related to connection establishment, see:
Chapter 4.4.3, "External RF and I/Q Settings", on page 135
Chapter 4.4.2, "I/Q Stream Mapper Settings", on page 132
For information on the manual and remote control operation of the external instru-
ments, see the documentation of the particular instrument:
For R&S SZU, see the SZU100A Getting Started
For R&S SGT, see the SGT100A User Manual
Control and Operation of External Instruments