Configuring the Internal Baseband Source
R&S
®
SMW200A
306User Manual 1175.6632.02 ─ 30
Clock Frequency
Displays or sets the ARB output clock rate.
The value of this parameter is set to the clock rate defined in the loaded waveform file
({CLOCK} tag). The value can be changed afterwards.
Note: The clock frequency must match the value of the externally applied clock source.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:CLOCk on page 1036
Delay
When Coupled sources are used, all basebands are triggered with a common trigger
signal.
Enable a time delay to delay the waveform processing of a particular baseband.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:COUPled:TRIGger:DELay:OFFSet
on page 1037
RF Power Ramping with Burst Marker
Option: R&S SMW-K22
If activated, the burst gate marker signal included in the ARB waveform file is used as
marker signal for the pulse modulator.
If this parameter is activated, but the loaded ARB waveform does not contain control
list or the burst gate marker is not defined, the ARB generator cannot be activated. An
error message indicates this situation, too.
You can create the suitable waveform files including the required burst gate marker sig-
nals, for example, with the R&S Pulse Sequencer software.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:PRAMp[:STATe] on page 1029
Create Multi Segment
Accesses the dialog for creating multi-segment waveforms (see Chapter 5.10, "Gener-
ating Multi-Segment Waveform Files", on page 351).
Create Multi Carrier
Accesses the dialog for creating multi-carrier waveforms (see Chapter 5.11, "Generat-
ing Multi-Carrier Signals", on page 381).
Test Signal Form
Selects the form of the test signal. A choice between a sinusoidal, rectangular, AWGN
or test signal with constant I/Q is provided.
To access further settings, select Create Test Signal.
"AWGN"
Requires R&S SMW-K811, see Chapter 5.8.4, "AWGN Test Signal",
on page 349.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:SIGNal:TYPE on page 1029
Using the Arbitrary Waveform Generator (ARB)