Remote Control Commands
R&S
®
SMW200A
1037User Manual 1175.6632.02 ─ 30
Parameters:
<Clock> float
Range: depends on the installed options
Increment: 0.001
*RST: 1E6
Default unit: Hz
E.g. 400 Hz to 200 MHz (R&S SMW-B10)
Example: See Example "Managing waveform files" on page 1020.
Manual operation: See "Clock Frequency" on page 306
[:SOURce<hw>]:BB:ARBitrary:COUPled:STATe <State>
In an instrument configuration with Coupled sources, selects that all basebands use
the same waveform.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
SCONfiguration:PRESet
SCONfiguration:MODE ADV
SCONfiguration:FADing SISO4X1X1
SCONfiguration:BASeband:SOURce COUP
SCONfiguration:APPLy
ENTity1:SOURce1:BB:ARBitrary:COUPled:STATe 0
ENTity1:SOURce1:BB:ARBitrary:WAVeform:SELect "/var/user/lte"
ENTity1:SOURce2:BB:ARBitrary:WAVeform:SELect "/var/user/lte"
ENTity1:SOURce3:BB:ARBitrary:WAVeform:SELect "/var/user/3gpp"
ENTity1:SOURce4:BB:ARBitrary:WAVeform:SELect "/var/user/gsm"
ENTity1:SOURce4:BB:ARBitrary:COUPled:TRIGger:DELay:OFFSet 100
SOURce1:BB:ARBitrary:STATe 1
Manual operation:
See "Use one Waveform for all basebands" on page 304
[:SOURce<hw>]:BB:ARBitrary:COUPled:TRIGger:DELay:OFFSet <Offset>
Sets a time delay to delay the waveform processing of a particular baseband.
Parameters:
<Offset> float
Range: 0 to 2147483647/clockrate
Increment: 250E-12
*RST: 0
Example: See [:SOURce<hw>]:BB:ARBitrary:COUPled:STATe
on page 1037.
Manual operation: See "Delay" on page 306
SOURce Subsystem