Signal Routing and System Configuration
R&S
®
SMW200A
182User Manual 1175.6632.02 ─ 30
"Previous Setting"
Resumes the state that was active before the last switch off.
Remote command:
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:PON on page 1146
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:PON on page 1146
Group Delay Compensation
(enabled for the BBMM connectors and connected R&S EX-IQ-BOX)
If you evaluate digital signals, enable this parameter so that the instrument compen-
sates the group delay response of the internal digital filters.
Remote command:
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:GDELay:CSTate on page 1149
4.8 I/Q Analog Output Settings
Required Options
The equipment layout for output of analog I/Q signal includes:
Option Standard Baseband Generator (R&S SMW-B10) per signal path and
Option Baseband main module, one/two I/Q paths to RF (R&S SMW-B13/-B13T)
Incl. output the baseband signal at the single-ended outputs
Option Differential Analog I/Q Outputs (R&S SMW-K16) per signal path
Or
Option Wideband Baseband Generator (R&S SMW-B9) per signal path and
Option Wideband baseband main module two I/Q paths to RF (R&S SMW-B13XT)
Incl. output the baseband signal at the single-ended outputs
Option Wideband Differential Analog I/Q Outputs (R&S SMW-K17)
One differential output; differential and single-ended signals cannot be output at the
same time.
Access
The analog output connectors I/Q x are located on the R&S SMW rear panel, see Fig-
ure 4-3.
The block diagram displays the "I/Q OUT 1/2" connector in a folded state. The analog
output connectors are inactive (gray LEDs).
I/Q Analog Output Settings

Table of Contents