Remote Control Commands
R&S
®
SMW200A
1188User Manual 1175.6632.02 ─ 30
Manual operation: See "Delta Phase" on page 471
[:SOURce<hw>]:PHASe:REFerence
Assigns the value set with command [:SOURce<hw>]:PHASe as the reference
phase.
Example: See Example "Programming Example" on page 1187.
Usage: Event
Manual operation: See "Reset Delta Phase Display" on page 471
14.19.16 SOURce:POWer Subsystem
The SOURce:POWer subsystem contains the commands for setting the output level,
level control and level correction of the RF signal.
The default units are dBm. To change the units, perform one of the following:
Enter the unit after the numerical value
Example: :POW 0.5V
Set the unit with the command :UNIT:POWer.
[:SOURce<hw>]:POWer:ALC:MODE?............................................................................1189
[:SOURce<hw>]:POWer:ALC[:STATe].............................................................................1189
[:SOURce<hw>]:POWer:ALC:DAMPlifier........................................................................ 1190
[:SOURce<hw>]:POWer:ALC:DSENsitivity......................................................................1190
[:SOURce<hw>]:POWer:ALC:SONCe............................................................................ 1190
[:SOURce<hw>]:POWer:ALC:SLEVel.............................................................................1191
[:SOURce<hw>]:POWer:ATTenuation.............................................................................1191
[:SOURce<hw>]:POWer:ATTenuation:DIGital..................................................................1191
[:SOURce<hw>]:POWer:ATTenuation:RFOFf:MODE........................................................1191
[:SOURce<hw>]:POWer:EMF:STATe..............................................................................1192
[:SOURce<hw>]:POWer:LBEHaviour............................................................................. 1192
[:SOURce<hw>]:POWer:LIMit[:AMPLitude]..................................................................... 1193
[:SOURce<hw>]:POWer:LMODe....................................................................................1193
[:SOURce<hw>]:POWer:MANual................................................................................... 1193
[:SOURce<hw>]:POWer:MODE.....................................................................................1194
[:SOURce<hw>]:POWer:PEP?...................................................................................... 1194
[:SOURce<hw>]:POWer:POWer.................................................................................... 1195
[:SOURce<hw>]:POWer:STARt..................................................................................... 1195
[:SOURce<hw>]:POWer:STOP......................................................................................1195
[:SOURce<hw>]:POWer:STEP:MODE............................................................................1195
[:SOURce<hw>]:POWer:STEP[:INCRement]...................................................................1196
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:OFFSet...................................................... 1196
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:RCL........................................................... 1197
[:SOURce<hw>]:POWer[:LEVel][:IMMediate][:AMPLitude]................................................ 1197
[:SOURce<hw>]:POWer:RANGe:LOWer?.......................................................................1198
[:SOURce<hw>]:POWer:RANGe:UPPer?....................................................................... 1198