EasyManua.ls Logo

Rohde & Schwarz R&S SMW200A - Mode

Rohde & Schwarz R&S SMW200A
1403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Signal Routing and System Configuration
R&S
®
SMW200A
133User Manual 1175.6632.02 ─ 30
The dialog provides the settings for routing of the signal streams to the available
output connectors, the analog RF and I/Q output, and the digital I/Q output connec-
tors.
Meaning of the background colors:
Yellow: Streams mapped to the RF, I/Q and the BBMM connectors can be
added, possibly also frequency and phase shifted. At the BBMM connectors,
streams can also be output multiplexed.
Gray: The stream mapping to the FADER connectors is fixed.
Only single streams can be mapped; frequency offset cannot be applied.
If R&S SMBV or R&S SGT instruments are connected to the FADER connec-
tors and they are remotely controlled by the R&S SMW, the selected frequency
offset is applied to the RF signal of these instruments.
The settings are displayed in form of a stream matrix, where:
The number of rows is equal to the number of the generated streams
("System Configuration > Fading/Baseband Configuration > Advanced Mode"
and selected Entities (Users, Cells)*Streams (Rx Antennas))
The column display only the available digital output interfaces ("System Config-
uration > External RF and I/Q > Direction > Out").
Settings:
f
offset
, MHz....................................................................................................................133
Phase Offset................................................................................................................134
Map Stream X to Connector........................................................................................134
Combination Mode......................................................................................................134
f
offset
, MHz
Option: R&S SMW-B9 - available if "Signal Outputs = Analog Only"
Sets an absolute frequency offset; streams routed to the RF, I/Q and BBMM connec-
tors are shifted in the frequency domain.
Frequency offset is also applied to R&S SMBV and R&S SGT instruments connected
to the FADER outputs.
Tip: Use this parameter:
To shift the used frequency band in the RF frequency section without modifying the
RF settings
To separate streams in the frequency domain, if these streams are added and
routed to the same output connector.
Note: The parameters "Baseband Offset" and "Frequency Offset" have different
impact.
Both parameters shift the signal in the frequency domain, but only the f
offset
affects the
calculation of the "Doppler Shift".
If the fading simulator is used, do not apply a "Baseband Offset" but do use the "Fre-
quency Offset" instead.
The value range depends on the following:
Installed options (e.g. baseband generator und baseband extensions)
"System Config > Fading/Baseband Config" > Mode
"System Config > Fading/Baseband Config" > Signal Outputs
For more information, see data sheet.
System Configuration Settings

Table of Contents